Unpack the device
Lift up the fan from the enclosed compartment located at the back of the device. Tighten it into position using a flat screwdriver.
Add a measure (spoon) of salt into the grinder, put the cover over the grinder and turn the device ON
How to set up the halogenerator Salt 1
How to set up the device
M M PERSONAL SERVICES, INC
344 W Hamlin Rd, Rochester Hills, MI 48307
Ph. 2488255462
Email: saltroombuilders@gmail.com
Website: www.saltroombuilders.com
Dear customer,
We thank you for buying our products; we are grateful and hope we’ll meet all your expectations. We’re here for you – at any time, you can count on us if you need answers regarding our products/services. We are available 24/7/365 at 2488255462 (we prefer text messages) or email: saltroombuilders@gmail.com. Please text/email us your email address in order for us to provide you a password that will allow you to access our Customers Portal page on www.saltroombuilders.com
Welcome to the beautiful world of Halotherapy.
SALT ONE HALOGENERATOR
BASIC INSTRUCTIONS MANUAL
I. PRECAUTIONS, WARNINGS
1. May cause electric shock or fire hazard
2. Do not use unsafe plugs or power
3. Do not install it in places where children can touch it
4. Advise adults not to touch it and not to allow children in their care to touch it
5. Do not install the device in places where it can’t be secured to prevent falling
6. Do not tilt the device
7. Keep the device away from fire and heat sources, do not store flammable around the device
8. Do not use or store the device in an environment with humidity higher than 50%
II. INSTALLATION
1. Unbox the device carefully, check the components, and read all the instructions
2. Install the device on a solid/firm surface and secure it to prevent falling
3. Lift the fan into the upper position and secure it by tightening the two sides fasteners using a Philips screwdriver
4. Check if the mill is moving freely
5. Place the cap over the mill with the side hole facing the fan
6. Plug the device and turn it ON from the left side switch
7. The device is already programmed at level 1 – notice if the fan, the mill, and the display are working without noise, squeaks, flares, etc
8. Let the device work for 45 minutes
9. Turn the device OFF and unplug it
10. Add a spoon of salt inside the mill, put the cap back, plugin the device, and turn it ON
11. Observe if the grinder works by observing a graphic indication on display: turn the lights off, point the flashlight at the mill cap, and notice salt aerosols coming out.
12. Keep the door of the device locked all the time, use the key provided
III. PROGRAMMING
1. The device has four buttons: BACK – return button
ENT – confirmation button
↑- increasing button
→- shift button
2. Change settings – are performed when the device is ON:
a. Press ↑ and → at the same time to enter the local time
b. Press for 3 seconds ENT button to turn ON/OFF the device
c. Press the > button to enter the working time and frequency setting interface.
3. Change the concentration of salt aerosols:
St = starting time, always should be 00:00
To = stop time, always should be 23:59
W = working time (001 – 999 seconds), the time when the grinder is ON
P = Pause time (001 – 999 seconds), the time when the grinder is OFF
The concentration of aerosols can be adjusted in 2 ways: by changing the duration W when the grinder works and by changing the time interval S when the grinder is stopped – there are unlimited possibilities for adjusting the aerosol concentration:
- increasing P, will decrease the concentration of aerosols
- decreasing P, will increase the concentration of aerosols
- increasing W, will increase the concentration of aerosols
- decreasing P will decrease the concentration of aerosols
We recommend that W should always be 30 seconds or less.
Always change the programming using Monday and Program1 – this way you’ll save the settings automtically. For instance, if you set for Monday with Program1 with W:15 seconds and P:70 seconds, this will automatically save the settings until you change them again:
a. Press the → button to enter the working time and frequency setting interface
b. Press ENT to confirm Monday
c. Press → multiple times until you are able to change W:15 and P:70 using ↑and → buttons
d. Press ENT to confirm your setting, this setting will be saved for the entire week
Halotherapy is not approved by the FDA and is not intended to prevent, diagnose, treat, or cure any disease. By buying this device, the buyer releases, discharges, indemnifies, defends, protects, and holds harmless MM Personal Services, Inc. from any and all claims, liabilities, demands, or injuries it may have against participation in Halotherapy.
IV OPERATION and MAINTENANCE
1. ALLWAYS perform maintenance operations when the device is OFF/unplugged.
2. Every day, before the first salt therapy session, check if the grinder blades are moving freely – sometimes, mainly because of humidity/not cleaning the grinder well, the blade might get stuck, and simply rotating it will free it. This daily routine is mandatory to ensure the long life of the motor/grinder mechanism.
3. At the end of every session – evacuate the residual salt from the grinder and add a new salt supply using the measure provided.
4. Check the aerosol production by dimming the lights inside the salt room and pointing the beam of the flashlight (provided)toward the grinder cap - you could show to your clients the flow of aerosols produced.
5. At the end of every day, clean up the grinder and the fan – this will ensure long-lasting life for your device.
For a better/faster cleaning process use an air duster device, just search “air duster” on Amazon. Alternatively, a duster can could be used.
6. Ensure that under any circumstances, the humidity inside the salt room is under 50%. If the Humidity exceeds 50%, remove the device from inside the salt room and clean it well using the air duster or brush, and a dry towel. Install the device inside the salt room after the humidity is under 50%.
7. If the fan needs to be replaced at one point, unmount the defective one and install the replacement fan provided. Always perform this operation with the device OFF and unplugged.
Not following the instruction regarding the operating, maintenance, working environment and cleaning procedures will waive the warranty.
V TROUBLESHOOTING
1. No power:
Make sure the device is plugged in and the switch is turned ON
Check if the electrical outlet is functional by plugging in a different device
check if the power supply is well inserted into the wall outlet or the halogenerator
Replace the power supply
2. Fan not working:
If the grinder works and the display is ON – the fan needs to be replaced – contact us for advice
3. The fan rotates slower than normal:
Salt accumulated on the blades, clean up the blades
The halogenerator is mounted too close to the wall
4. Grinder not working:
Observe the display on the halogenerator when it shows W in progress
Unplug the device, clean up the grinder of residual salt
With the halogenerator unplugged rotate the blades by hand, if not rotating at all – the motor is blocked – contact us
5. Any unusual noises, or behavior – observe the cause and eliminate it if possible, if not – contact us.
6. No salt aerosols production:
The grinder or the fan not working or working improperly – see above
The salt used is too humid – dry the salt before using it according to the instructions
The cap’s grinder side and the top hole are clogged with salt – clean up, unclog the cap
Use the flashlight to check the aerosol production
7. If possible, send us a short video clip that will show your device’s issue.
SALT ONE HALOGENERATOR
BASIC INSTRUCTIONS MANUAL
I. PRECAUTIONS, WARNINGS
1. May cause electric shock or fire hazard
2. Do not use unsafe plugs or power
3. Do not install it in places where children can touch it
4. Advise adults not to touch it and not to allow children in their care to touch it
5. Do not install the device in places where it can’t be secured to prevent falling
6. Do not tilt the device
7. Keep the device away from fire and heat sources, do not store flammable around the device
8. Do not use or store the device in an environment with humidity higher than 50%
II. INSTALLATION
1. Unbox the device carefully, check the components, and read all the instructions
2. Install the device on a solid/firm surface and secure it to prevent falling
3. Lift the fan into the upper position and secure it by tightening the two sides fasteners using a Philips screwdriver
4. Check if the mill is moving freely
5. Place the cap over the mill with the side hole facing the fan
6. Plug the device and turn it ON from the left side switch
7. The device is already programmed at level 1 – notice if the fan, the mill, and the display are working without noise, squeaks, flares, etc
8. Let the device work for 45 minutes
9. Turn the device OFF and unplug it
10. Add a spoon of salt inside the mill, put the cap back, plugin the device, and turn it ON
11. Observe if the grinder works by observing a graphic indication on display: turn the lights off, point the flashlight at the mill cap, and notice salt aerosols coming out.
12. Keep the door of the device locked all the time, use the key provided
III. PROGRAMMING
1. The device has four buttons: BACK – return button
ENT – confirmation button
↑- increasing button
→- shift button
2. Change settings – are performed when the device is ON:
a. Press ↑ and → at the same time to enter the local time
b. Press for 3 seconds ENT button to turn ON/OFF the device
c. Press the > button to enter the working time and frequency setting interface.
3. Change the concentration of salt aerosols:
St = starting time, always should be 00:00
To = stop time, always should be 23:59
W = working time (001 – 999 seconds), the time when the grinder is ON
P = Pause time (001 – 999 seconds), the time when the grinder is OFF
The concentration of aerosols can be adjusted in 2 ways: by changing the duration W when the grinder works and by changing the time interval S when the grinder is stopped – there are unlimited possibilities for adjusting the aerosol concentration:
- increasing P, will decrease the concentration of aerosols
- decreasing P, will increase the concentration of aerosols
- increasing W, will increase the concentration of aerosols
- decreasing P will decrease the concentration of aerosols
We recommend that W should always be 30 seconds or less.
Always change the programming using Monday and Program1 – this way you’ll save the settings automtically. For instance, if you set for Monday with Program1 with W:15 seconds and P:70 seconds, this will automatically save the settings until you change them again:
a. Press the → button to enter the working time and frequency setting interface
b. Press ENT to confirm Monday
c. Press → multiple times until you are able to change W:15 and P:70 using ↑and → buttons
d. Press ENT to confirm your setting, this setting will be saved for the entire week
Halotherapy is not approved by the FDA and is not intended to prevent, diagnose, treat, or cure any disease. By buying this device, the buyer releases, discharges, indemnifies, defends, protects, and holds harmless MM Personal Services, Inc. from any and all claims, liabilities, demands, or injuries it may have against participation in Halotherapy.
SALT ONE HALOGENERATOR
BASIC INSTRUCTIONS MANUAL
I. PRECAUTIONS, WARNINGS
1. May cause electric shock or fire hazard
2. Do not use unsafe plugs or power
3. Do not install it in places where children can touch it
4. Advise adults not to touch it and not to allow children in their care to touch it
5. Do not install the device in places where it can’t be secured to prevent falling
6. Do not tilt the device
7. Keep the device away from fire and heat sources, do not store flammable around the device
8. Do not use or store the device in an environment with humidity higher than 50%
II. INSTALLATION
1. Unbox the device carefully, check the components, and read all the instructions
2. Install the device on a solid/firm surface and secure it to prevent falling
3. Lift the fan into the upper position and secure it by tightening the two sides fasteners using a Philips screwdriver
4. Check if the mill is moving freely
5. Place the cap over the mill with the side hole facing the fan
6. Plug the device and turn it ON from the left side switch
7. The device is already programmed at level 1 – notice if the fan, the mill, and the display are working without noise, squeaks, flares, etc
8. Let the device work for 45 minutes
9. Turn the device OFF and unplug it
10. Add a spoon of salt inside the mill, put the cap back, plugin the device, and turn it ON
11. Observe if the grinder works by observing a graphic indication on display: turn the lights off, point the flashlight at the mill cap, and notice salt aerosols coming out.
12. Keep the door of the device locked all the time, use the key provided
III. PROGRAMMING
1. The device has four buttons: BACK – return button
ENT – confirmation button
↑- increasing button
→- shift button
2. Change settings – are performed when the device is ON:
a. Press ↑ and → at the same time to enter the local time
b. Press for 3 seconds ENT button to turn ON/OFF the device
c. Press the > button to enter the working time and frequency setting interface.
3. Change the concentration of salt aerosols:
St = starting time, always should be 00:00
To = stop time, always should be 23:59
W = working time (001 – 999 seconds), the time when the grinder is ON
P = Pause time (001 – 999 seconds), the time when the grinder is OFF
The concentration of aerosols can be adjusted in 2 ways: by changing the duration W when the grinder works and by changing the time interval S when the grinder is stopped – there are unlimited possibilities for adjusting the aerosol concentration:
- increasing P, will decrease the concentration of aerosols
- decreasing P, will increase the concentration of aerosols
- increasing W, will increase the concentration of aerosols
- decreasing P will decrease the concentration of aerosols
We recommend that W should always be 30 seconds or less.
Always change the programming using Monday and Program1 – this way you’ll save the settings automtically. For instance, if you set for Monday with Program1 with W:15 seconds and P:70 seconds, this will automatically save the settings until you change them again:
a. Press the → button to enter the working time and frequency setting interface
b. Press ENT to confirm Monday
c. Press → multiple times until you are able to change W:15 and P:70 using ↑and → buttons
d. Press ENT to confirm your setting, this setting will be saved for the entire week
Halotherapy is not approved by the FDA and is not intended to prevent, diagnose, treat, or cure any disease. By buying this device, the buyer releases, discharges, indemnifies, defends, protects, and holds harmless MM Personal Services, Inc. from any and all claims, liabilities, demands, or injuries it may have against participation in Halotherapy.
SALT ONE HALOGENERATOR
BASIC INSTRUCTIONS MANUAL
I. PRECAUTIONS, WARNINGS
1. May cause electric shock or fire hazard
2. Do not use unsafe plugs or power
3. Do not install it in places where children can touch it
4. Advise adults not to touch it and not to allow children in their care to touch it
5. Do not install the device in places where it can’t be secured to prevent falling
6. Do not tilt the device
7. Keep the device away from fire and heat sources, do not store flammable around the device
8. Do not use or store the device in an environment with humidity higher than 50%
II. INSTALLATION
1. Unbox the device carefully, check the components, and read all the instructions
2. Install the device on a solid/firm surface and secure it to prevent falling
3. Lift the fan into the upper position and secure it by tightening the two sides fasteners using a Philips screwdriver
4. Check if the mill is moving freely
5. Place the cap over the mill with the side hole facing the fan
6. Plug the device and turn it ON from the left side switch
7. The device is already programmed at level 1 – notice if the fan, the mill, and the display are working without noise, squeaks, flares, etc
8. Let the device work for 45 minutes
9. Turn the device OFF and unplug it
10. Add a spoon of salt inside the mill, put the cap back, plugin the device, and turn it ON
11. Observe if the grinder works by observing a graphic indication on display: turn the lights off, point the flashlight at the mill cap, and notice salt aerosols coming out.
12. Keep the door of the device locked all the time, use the key provided
III. PROGRAMMING
1. The device has four buttons: BACK – return button
ENT – confirmation button
↑- increasing button
→- shift button
2. Change settings – are performed when the device is ON:
a. Press ↑ and → at the same time to enter the local time
b. Press for 3 seconds ENT button to turn ON/OFF the device
c. Press the > button to enter the working time and frequency setting interface.
3. Change the concentration of salt aerosols:
St = starting time, always should be 00:00
To = stop time, always should be 23:59
W = working time (001 – 999 seconds), the time when the grinder is ON
P = Pause time (001 – 999 seconds), the time when the grinder is OFF
The concentration of aerosols can be adjusted in 2 ways: by changing the duration W when the grinder works and by changing the time interval S when the grinder is stopped – there are unlimited possibilities for adjusting the aerosol concentration:
- increasing P, will decrease the concentration of aerosols
- decreasing P, will increase the concentration of aerosols
- increasing W, will increase the concentration of aerosols
- decreasing P will decrease the concentration of aerosols
We recommend that W should always be 30 seconds or less.
Always change the programming using Monday and Program1 – this way you’ll save the settings automtically. For instance, if you set for Monday with Program1 with W:15 seconds and P:70 seconds, this will automatically save the settings until you change them again:
a. Press the → button to enter the working time and frequency setting interface
b. Press ENT to confirm Monday
c. Press → multiple times until you are able to change W:15 and P:70 using ↑and → buttons
d. Press ENT to confirm your setting, this setting will be saved for the entire week
Halotherapy is not approved by the FDA and is not intended to prevent, diagnose, treat, or cure any disease. By buying this device, the buyer releases, discharges, indemnifies, defends, protects, and holds harmless MM Personal Services, Inc. from any and all claims, liabilities, demands, or injuries it may have against participation in Halotherapy.
M M PERSONAL SERVICES, INC
344 W Hamlin Rd, Rochester Hills, MI 48307
Ph. 2488255462
Email: saltroombuilders@gmail.com
Website: www.saltroombuilders.com
Dear customer,
We thank you for buying our products; we are grateful and hope we’ll meet all your expectations.
We’re here for you – at any time, you can count on us if you need answers regarding our products/services. Also, we will do our best to answer your questions regarding setting and operating the salt room.
Welcome to the beautiful world of Halotherapy.
SALT ONE HALOGENERATOR
BASIC INSTRUCTIONS MANUAL
I. PRECAUTIONS, WARNINGS
1. May cause electric shock or fire hazard
2. Do not use unsafe plugs or power
3. Do not install it in places where children can touch it
4. Advise adults not to touch it and not to allow children in their care to touch it
5. Do not install the device in places where it can’t be secured to prevent falling
6. Do not tilt the device
7. Keep the device away from fire and heat sources, do not store flammable around the device
8. Do not use the device in a hot environment
9. Do not use or store the device in an environment with humidity higher than 40%
II. INSTALLATION
1. Unbox the device carefully, check the components, and read all the instructions
2. Install the device on a solid/firm surface and secure it to prevent falling
3. Lift the fan into the upper position and secure it by tightening the two sides fasteners using a Philips screwdriver
4. Check if the mill is moving freely
5. Place the cap over the mill with the side hole facing the fan
6. Plug the device and turn it ON from the left side switch
7. The device is already programmed at level 1 – notice if the fan, the mill, and the display are working without noise, squeaks, flares, etc
8. Let the device work for 45 minutes
9. Turn the device OFF and unplug it
10. Add a spoon of salt inside the mill, put the cap back, plug the device, and power it
11. Observe if the grinder works by observing a graphic indication on display – turn the lights off, point the flashlight at the mill cap, and notice salt aerosols coming out.
12. Keep the door of the device locked with the key provided all the time
III. PROGRAMMING
1. The device has four buttons: BACK – return button
ENT – confirmation button
↑- increasing button
→- shift button
2. Change settings – all are performed when the device is ON:
a. Press ↑ and → at the same time to enter the local time
b. Press for 3 seconds ENT button to turn ON/OFF the device
c. Press the > button to enter the working time and frequency setting interface.
3. Change the concentration of salt aerosols:
St = starting time, always should be 00:00
To = stop time, always should be 23:59
W = working time (001 – 999 seconds), the time when the grinder is ON
P = Pause time (001 – 999 seconds), the time when the grinder is OFF
The concentration of aerosols can be adjusted in 2 ways: by changing the duration W when the grinder works and by changing the time interval S when the grinder is stopped – there are unlimited possibilities for adjusting the aerosol concentration:
- increasing P, will decrease the concentration of aerosols
- decreasing P, will increase the concentration of aerosols
- increasing W, will increase the concentration of aerosols
- decreasing P will decrease the concentration of aerosols
We recommend that W should always be 15 seconds or less.
Always change the programming using Monday and Program1 – this way you’ll save the settings for the entire week. For instance, if you set for Monday with Program1 with W:15 seconds and P:70 seconds, this will automatically save the setting for the entire week:
a. Press the → button to enter the working time and frequency setting interface
b. Press ENT to confirm Monday
c. Press → multiple times until you are able to change W:15 and P:70 using ↑and → buttons
d. Press ENT to confirm your setting, this setting will be saved for the entire week
Halotherapy is not approved by the FDA and is not intended to prevent, diagnose, treat, or cure any disease.
By buying this device, the buyer releases, discharges, indemnifies, defends, protects, and holds harmless MM Personal Services, Inc. from any and all claims, liabilities, demands, or injuries it may have against participation in Halotherapy.
IV OPERATION and MAINTENANCE
1. ALLWAYS perform maintenance operations when the device is OFF/unplugged.
2. Every day, before the first salt therapy session, check if the grinder blades are moving freely – sometimes, mainly because of humidity/not cleaning the grinder well, the blade might get stuck, and simply rotating it will free it. This daily routine is mandatory to ensure the long life of the motor/grinder mechanism.
3. At the end of every session – evacuate the residual salt from the grinder and add a new salt supply using the measure provided.
4. Check the aerosol production by dimming the lights inside the salt room and pointing the beam of the flashlight (provided)toward the grinder cap - you could show to your clients the flow of aerosols produced.
5. At the end of every day, clean up the grinder and the fan using the blower provided – this will ensure long-lasting life for your device. Make sure the blades are free of salt. Use the brush provided. For a better/faster cleaning process use an air duster device with rechargeable batteries. To buy one (about $20) just search “air duster” on Amazon.
6. Ensure that under any circumstances, the humidity inside the salt room is under 40%. If the Humidity exceeds 40%, remove the device from inside the salt room and clean it well using the air duster or brush, and a dry towel. Install the device inside the salt room after the humidity is under 40%.
7. If the fan needs to be replaced at one point, unmount the defective one and install the replacement fan provided. Always perform this operation with the device OFF and unplugged.
V TROUBLESHOOTING
1. No power:
Make sure the device is plugged in and the switch is turned ON
Check if the electrical outlet is functional by plugging in a different device
check if the power supply is well inserted into the wall outlet or the halogenerator
Replace the power supply
2. Fan not working:
If the grinder works and the display is ON – the fan needs to be replaced – contact us for advice
3. The fan rotates slower than normal:
Salt accumulated on the blades, clean up the blades
The halogenerator is mounted too close to the wall
4. Grinder not working:
Observe the display on the halogenerator when it shows W in progress
Unplug the device, clean up the grinder of residual salt
With the halogenerator unplugged rotate the blades by hand, if not rotating at all – the motor is blocked – contact us
Op
5. Any unusual noises, or behavior – observe the cause and eliminate it if possible, if not – contact us.
6. No salt aerosols production:
The grinder or the fan not working or working improperly – see above
The salt used is too humid – dry the salt before using it according to the instructions
The cap’s grinder side and the top hole are clogged with salt – clean up, unclog the cap
Use the flashlight to check the aerosol production
7. If possible, send us a short video clip that will show your device’s issue.
If you have questions, we are available 24/7/365 at 2488255462 (we prefer text messages) or email: saltroombuilders@gmail.com.
Additional info can be found on our website, www.saltroombuilders.com.
PHARMACEUTICAL GRADE SALT
For best results in Halotherapy, only pharmaceutical-grade sodium chloride of small granulation is required, dry and free of additives. We do not advise using other salts, such as sea salt, iodized salt, or Himalayan salt, as these contain other ingredients besides sodium chloride.
The salt used in Halotherapy needs to undergo a few steps:
Unpacking and checking granulation, impurities, and clumps. If granulation is higher than standard USP sodium chloride – do not use it. Salt is highly hygroscopic – it will attract humidity from the environment and may form clumps. If clumps are present – use a kitchen mortar to break them.
The drying process is essential in creating high-quality salt aerosols with true therapeutic values: under 1-micron size, weight light that will be airborne farther into the salt room and stay longer in the air. Equally important, small dry aerosols will travel deeper into the airways and have an enhanced therapeutic effect.
To properly dry sodium chloride, use a stainless steel or glass pot without cover, pour the salt into the pot no more than one inch thick, and heat the pot to 270F using either an electric induction plate or a convection oven (do not use a microwave oven!). Keep the pot at 270F for one hour and occasionally stir; this way, the humidity is eliminated from sodium chloride. Keep the dry salt in an air-sealed container (with a cap) filled with salt to the top. Over time, after using part of the salt, place a larger sachet of silica inside the container to absorb the humidity from the air inside the container. Keep the container closed all the time.
.
Welcome! Please call us at 2488255462 for free consulting